Created on 12/07/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 1 of 2
MODEL
CBAGX
Fixed setting, 4.5:1 pilot ratio, ultra-restrictive counterbalance valve
SERIES 1 / CAPACITY: 10 L/min. / CAVITY: T-11A
3-Port Non-vented, Fixed Setting
Fixed-setting, 3-port counterbalance valves with pilot assist function similarly to the adjustable versions except the
fixed setting is pre-set to a nominal value. These fixed-setting valves are meant to control an overrunning load. The
check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-
assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief
valve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATA
Pilot Ratio 4.5:1
Factory Pressure Settings Established at 30 cc/min.
Maximum Valve Leakage at Reseat 0,3 cc/min.
Check Cracking Pressure 1,7 bar
Seal kit - Cartridge Buna: 990-011-007
Seal kit - Cartridge Polyurethane: 990-011-002
Seal kit - Cartridge Viton: 990-011-006
(M)FIXED PRESSURE RANGE
M 4700 - 5600 psi (325 - 390 bar)
V 3200 - 3800 psi (220 - 260 bar)
X 3500 - 4200 psi (245 - 290 bar)
Z 4125 - 4900 psi (285 - 340 bar)
(N)SEAL MATERIAL
N Buna-N
V Viton
MATERIAL/COATING
Standard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CBAGX
TECHNICAL FEATURES
Restrictive valves have no relief capacity other than as a thermal relief.
The maximum recommended load pressure for the M range is 3600 psi (250 bar). The highest cracking pressure for the M range will be less than 5600 psi (390
bar).
The maximum recommended load pressure for the V range is 2450 psi (170 bar). The highest cracking pressure for the V range will be less than 3800 psi (260 bar).
The maximum recommended load pressure for the X range is 2700 psi (190 bar). The highest cracking pressure for the X range will be less than 4200 psi (290 bar).
The maximum recommended load pressure for the Z range is 3170 psi (220 bar). The highest cracking pressure for the Z range will be less than 4900 psi (340 bar).
Note: The pressures listed under RANGE are approximate, mean values and should not be used for inspection purposes.
Note: The percentage difference between the cracking and reseat values for the fixed and adjustable versions of this valve are identical. However, the cracking
point for the adjustable control can be set via the adjustment mechanism to within +/- 50 psi (3,5 bar) of the specified value. In the case of the fixed-setting version,
the setting tolerance can only be maintained within a several hundred psi span, depending on the range. The maximum recommended load pressure for any given
range is the minimum possible setting divided by 1.3.
Fixed-setting counterbalance valves offer a shorter cartridge extension than the adjustable version.
Fixed-setting counterbalance valves can be used to protect cylinder seals in outrigger circuits from damage due to thermal expansion, however, they probably
should not be applied in circuits in which a matched valve setting may be required such as dual cylinder applications.
Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
This valve has positive seals between all ports.
Model Code Example: CBAGXMNCONFIGURATION OPTIONS
Created on 12/07/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 2 of 2
All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES
RELATED MODELS
CBAG 4.5:1 pilot ratio, ultra-restrictive counterbalance valve